欢迎来到010在线作文网!

医学护理的论文

实用文 时间:2021-08-31 手机版

  医学护理是一个非常火热的专业,下面就是小编为您收集整理的医学护理的论文的相关文章,希望可以帮到您,如果你觉得不错的话可以分享给更多小伙伴哦!

  医学护理的论文一

  [摘要] 术中神经监测(IONM)作为手术的辅助手段,是指应用神经电生理技术,观察神经的连续性、监测神经系统的电生理传导功能,了解手术过程中有无神经损伤。 甲状腺手术的难点在于术中对喉神经的保护,但 IONM 可以很好地判断喉返神经损伤的程度,作为一种很有发展前景的工具,IONM 在甲状腺手术中的运用已在国内外得到广泛的论证、研究和应用。 拟对当前 IONM 在甲状腺手术中的应用研究进行综述。

  [关键词] 术中神经功能监测;甲状腺手术;喉返神经。

  [Abstract] The intraoperative neuromonitoring technology(IONM) as an auxiliary means of surgery refers tousing neural electrophysiological technique to observe nerve continuity,to monitor nervous system electrophysiologicalconduction function and to detect neurological injury in the thyroid surgery. If it is difficult to protect laryngealnerve in thyroid surgery,but IONM is just easy to judge the injury aegree of laryngeal nerve. Now IONM hasbeen widely used in the thyroid surgery at home and abroad. In this paper,authors merely reviewed the recurrentapplication and research of IONM in the thyroid surgery.

  [Key words] Intraoperative neuromonitoring technology(IONM);Thyroid surgery;Laryngeal nerve.

  在甲状腺手术之前,为了减少神经损伤和声带疾病的发病概率,鉴定喉返神经是一种安全有效的预防措施。 但在中心淋巴结清除、甲状腺功能亢进、甲状腺肿大以及甲状腺炎患者中,安全鉴定神经并保持神经的功能很难实现。 手术过程中的神经功能监测(intra operative neuro monitoring,IONM)已在神经医学中广泛应用[1-3].在甲状腺手术中运用神经监测仪是 Shedd 及 Flisberg 分别于 1966 年和 1970年提出,这一方法可直接通过电生理刺激,观察神经的连续性和电生理传导功能,帮医师辅助了解手术过程中喉神经的损伤。 随着监测设备和监测步骤的不断改进,在甲状腺手术之前,利用 IONM 标准化鉴定喉返神经 (recurrent laryngeal nerve,RLN),成为预防喉神经损伤的辅助手段。 在以上背景下,在过去 10 年里,IONM 已被外科医师广泛接受:在欧美国家甲状腺术中神经监测普及率达到 40%~90%;在我国此技术也逐渐被认可和推广。 在 IONM取得可喜的发展的同时,仍然有许多的技术难题等待医学科学家的研究。 因此该文综述了多个研究组在这一方向的最新研究[2-15],并简述 IONM 的新应用方向。

  1 IONM 可有效降低 RLN 损伤。

  有研究显示,在甲状腺手术过程中,当运用标准的 IONM 之后,和之前的神经可视化的金标准相比,RLN 偏瘫的概率减少了[3,16]. Barczynski 在 2013年的研究中发现,在重复甲状腺手术中,和神经可视化相比,IONM 可以减少 RLN 麻痹的发生率[17].具体来看,当使用 IONM 时,短暂的和永久的 RLN创伤都被发现, 频率分别是 2.6%和 1.4%; 而不用IONM 的话,是 6.3%和 2.4%[17]. 当然也有研究认为这种减少并不显着[18].

  不论如何,IONM 有着不可比拟的优点:明确神经的位置, 避免手术过程破坏 RLN 和可能的神经分支;在手术前、手术中及手术后,监测喉神经的功能,证实神经在生理学上的完整性。 由于甲状腺再手术以及具有非典型过程的首次手术都将导致神经麻痹率的增高[3,19],在这 些情况 下 IONM 所 具有的优点将更有利于保护手术对神经的损伤。 另外,在甲状腺疾病的手术过程中,外科医师必须熟记操作(甲状腺疾病操作、颈部以及 RLN 解剖),这是非常困难的。在这一情况下,IONM 的应用更是显得不可缺少了。

  有研究显示中心室颈淋巴结清扫术(centralcompartment neck dissection,CCND)并不会增加甲状腺切除术导致 RLN 偏瘫的风险[20]. 那么在 CCND中,针对 IONM 的作用便产生了争议。 不过,IONM可以更有效地鉴定神经并对神经的状态进行客观的监测,尤其是当解剖学变体存在时。 这将会将双边神经麻痹的危险降低到最低状态。

  另外,在 CCND 手术过程中,视野内缺少针对神经的解剖学标记,还含有大量的伤痕组织。 在这种情况下,IONM 还可以帮助医师鉴定视野内的RLN,以避免破坏解剖盲区的神经[21].

  2 IONM 的研究进展。

  当前针对 IONM 的研究可被分为两个方面:动物实验模型以及临床观察研究。

  2.1 动物实验模型 由于人类疾病的复杂性以及以人本身作为实验对象的局限性,要将有科学意义的发现转化为对人类有现实意义的技术,特别是最新的外科手术技术(比如 IONM),都需要开发出合适的动物模型。 IONM 动物实验模型可以用来测试不同的麻醉,手术装备,外科手术程序,新的手术方法手段,以及测试因为 IONM 而产生的神经创伤。

  现在已经有多种针对 IONM 的动物实验模型已在最新的研究中运用,比如:猪或医用迷你猪实验模型[7,22-28],狗实验模型[29,30]和老鼠实验模型[31].猪实验模型是最常用的动物实验模型,因为猪和人在结构以及生理上是相似的, 尤其是颈部和喉部。另外,与灵长类、猫和狗实验模型相比,医用迷你猪实验模型非常经济划算,花费相对较低。

  当前动物 IONM 模型主要用于以下四个方面的研究:(1)测试安全标准的气管肌电图(electrom-yographic endotracheal,EMG)数据。 Wu 等[12]构建了一个很有潜力的猪实验模型, 用它来测试安全性,并且调查在 IONM 过程中迷走神经 (vagus nerve,VN)和 RLN 刺激的最佳电子强度。 他们在连续性刺激 VN 和 RLN 10 min 后, 并没有发现不常见的电生理或心肺影响。 (2)麻醉观察。 神经肌肉的阻断药(neuromuscular blocking agents,NMBAs) 可以减少IONM 过程中声带肌肉的 EMG 信号。 Lu[7,24]以猪作为研究对象,调查了 IONM 过程中 NMBAs 的效果,比较了不同药物对喉肌的恢复谱,并且将这一信息引入到临床应用中。 (3) 新方法的可行性研究。Witzel 等[25]运用猪实验模型测试了在经口咽入路甲状腺切除术中,IONM 运用的可行性。 Schneider 等[22]运用猪实验模型测试并证实了运用新的迷走神经卯电极来延续 IONM 的可行性。 (4)神经创伤研究。在 IONM 过程中产生的 RLN 创伤有着不同的类型,包括横断损伤[26,27],夹紧损 伤和 挤压损 伤[26,28,29,32],牵拉损伤或压伤[22,26]以及热创伤[22,26,31]都已被研究。并且, 他们的 EMG 信号都被记录并且找到了这些信号和相应神经损伤的联系。

  2.2 临床研究 当前针对 IONM 的临床观察研究主要在以下四个方面:(1)麻醉观察时肌肉松弛药的运用(神经肌肉阻滞药,NMBAs)。 在全身麻醉时,对患者注射 NMBAs 是必须的。 这样可以获得临床上可接受的气管插管条件,并且还可以阻止喉部的创伤。 但是 NMBAs 还是 IONM 过程中产生假阴性反应的潜在原因。 在以前的研究中,中国研究组已经检测了对患者注射非去极化 NMBAs(单剂量的阿曲库铵或罗库溴铵)后,IONM 的可行性[33,34]. 他们同样证实了 95%有效药物剂量的罗库溴铵(0.3 mg/kg)是 IONM 的最 佳剂 量[35]. (2)麻醉观察时 EMG气管内导管的安置。 气管内导管表面电极的错位将会导致装置故障或监测的失败, 并给出错误的信息,这些错误信息将增加 RLN 创伤发生率。 Chiang研究组[36]调查了 EMG 导管的最佳深度,总结了对如何检测电极异位有参考价值的信息,并且探讨了在手术过程中如何校准导管的深度。 另外的研究也发现[8],当患者的头部位置从气管插管的中立位置变成甲状腺手术的全部牵引时, 电极即可被移去。因此他们认为当患者被定位之后,应该运用喉镜检测电极的常规位置。 (3)创新应用。 现阶段一些创新性的 IONM 应用已被探讨研究,包括:外科手术易错点的阐明以及 RLN 创伤的机理[37,38];VN 刺激技术中, 技术问题的解决,RLN 损伤的识别,RLN 手术后功能的精准监测[6,18,38,39],以及 非喉返 神经的检测[40-42];早期 RLN 位置的鉴定[43],鉴定并处置神经结构上的变化[44,45],广阔范围的 RLN 解剖[46];喉上神经外支(external branch of the superior laryngealnerve,EBSLN)的'监测技术[2];CIONM 的可行性分析及具体策略[22].

  3 小 结。

  针对甲状腺手术来说, 现在正处于转型期,即从 RLN 的形象化识别到 RLN 的神经生理学识别。在甲状腺手术时, 针对患者 RLN 医师所具备的知识应该包括:RLN 解剖学知识、 神经的常规图像鉴定、RLN 的颈部暴露、手术经验的积累、训练以及手术喉镜观察。 可以看到随着时间的流逝,这些知识都在发生变化,并且新的技术也逐步加入到甲状腺手术中。

  现在来看 IONM 仍然有值得研究探讨的问题:(1)需要标准化的手术操作以及更标准的训练来避开手术过程中的常犯错误;(2)对于常见的手术陷阱,医师应具备更深的知识储备,并且具备避免错误排除错误的能力;(3)对 RLN 神经生理学需做进一步的研究。

  参考文献:

  [1] Randolph GW,Dralle H,Abdullah H,et al. Electrophysiologicrecurrent laryngeal nerve monitoring during thyroid and para-thyroid surgery: International Standards Guideline Statement[J].Laryngoscope,2011,121(S1):S1-S16.

  [2] Barczynski M,Randolph GW,Cernea CR,et al. External branchof the superior laryngeal nerve monitoring during thyroid andparathyroid surgery:International Neural Monitoring Study Groupstandards guideline statement[J]. Laryngoscope,2013,123(S4):S1-S14.

  [3] Dionigi G,Barczynski M,Chiang FY,et al. Why monitor therecurrent laryngeal nerve in thyroid surgery?[J]. Journal of En-docrinological Investigation,2010,33(11):819-822.

  [4] Dionigi G,Kim HY,Wu CW,et al. Vagus nerve stimulation forstandardized monitoring: technical notes for conventional andendoscopic thyroidectomy[J]. Surg Technol Int,2013,23(9):95-103.

  [5] Wu CW,Dionigi G,Chen HC,et al. Vagal nerve stimulationwithout dissecting the carotid sheath during intraoperative neu-romonitoring of the recurrent laryngeal nerve in thyroid surgery[J]. Head Neck J Sci Spec,2013,35(10):1443-1447.

  [6] Dionigi G,Chiang FY,Rausei S,et al. Surgical anatomy andneurophysiology of the vagus nerve(VN) for standardised intra-operative neuromonitoring(IONM) of the inferior laryngeal nerve(ILN) during thyroidectomy [J]. Langenbeck Arch Surg,2010,395(7):893-899.

  [7] Lu IC,Chang PY,Hsu HT,et al. A comparison between succ-inylcholine and rocuronium on the recovery profile of the lar-yngeal muscles during intraoperative neuromonitoring of therecurrent laryngeal nerve:A prospective porcine model[J]. Kao-hsiung J Med Sci,2013,29(9):484-487.

  [8] Tsai CJ,Tseng KY,Wang FY,et al. Electromyographic endotra-cheal tube placement during thyroid surgery in neuromonitoringof recurrent laryngeal nerve[J]. Kaohsiung J Med Sci,2011,27(3):96-101.

  [9] Chiang FY,Lee KW,Chen HC,et al. Standardization of intrao-perative neuromonitoring of recurrent laryngeal nerve in thyroidoperation[J]. World J Surg,2010,34(11):223-229.

  [10] Dionigi G,Alesina PF,Barczynski M,et al. Recurrent laryngealnerve injury in video-assisted thyroidectomy:lessons learnedfrom neuromonitoring[J]. Surgical Endoscopy and Other Inter-ventional Techniques,2012,26(9):2601-2608.

  [11] Friedrich C,Ulmer C,Rieber F,et al. Safety analysis of vagalnerve stimulation for continuous nerve monitoring during thy-roid surgery[J]. Laryngoscope,2012,122(9):1979-1987.

  [12] Luginbuhl A,Schwartz DM,Sestokas AK,et al. Detection ofevolving injury to the brachial plexus during transaxillary ro-botic thyroidectomy[J]. Laryngoscope,2012,122(9):110-115.

  [13] Imperatori A,Dionigi G,De Monte,et al. Cervico-mediastinalschwannoma of the vagus nerve: resection with intraoperativenerve monitoring[J]. Updates Surg,2011,63(1):59-61.

  [14] Zhong D,Zhou Y,Li Y,et al. Intraoperative recurrent laryngealnerve monitoring: a useful method for patients with esophagealcancer[J]. Diseases of the Esophagus,2014,27(5):444-451.

  [15] Gelpke H,Grieder F,Decurtins M,et al. Recurrent laryngealnerve monitoring during esophagectomy and mediastinal lymphnode dissection[J]. World J Surg,2010,34(10):2379-2382.

  [16] Barczynski M,Konturek A,Cichon S. Randomized clinical trialof visualization versus neuromonitoring of recurrent laryngealnerves during thyroidectomy[J]. Br J Surg,2009,96(3):240-246.

  [17] Barczynski M,Konturek A,Pragacz K,et al. Intraoperative nervemonitoring can reduce prevalence of recurrent laryngeal nerveinjury in thyroid reoperations:Results of a retrospective cohortstudy[J]. World Journal of Surgery,2014,38(4):599-606.

  [18] Dralle H,Sekulla C,Lorenz K,et al. Intraoperative monitoringof the recurrent laryngeal nerve in thyroid surgery[J]. WorldJ Surg,2008,32(7):1358-1366.

  [19] Sancho JJ,Pascual-Damieta M,Pereira JA,et al. Risk factorsfor transient vocal cord palsy after thyroidectomy [J]. Br JSurg,2008,95(10):961-967.

  [20] Giordano D,Valcavi R,Thompson GB,et al. Complications ofcentral neck dissection in patients with papillary thyroid car-cinoma:Results of a study on 1087 patients and review ofthe literature[J]. Thyroid,2012,22(3):911-917.

  [21] Alesina PF,Rolfs T,Hommeltenberg S,et al. Intraoperativeneuromonitoring does not reduce the incidence of recurrentlaryngeal nerve palsy in thyroid reoperations:Results of a re-trospective comparative analysis[J]. World Journal of Surgery,2012,36(4):1348-1353.

  [22] Schneider R,Przybyl J,Pliquett U,et al. A new vagal anchorelectrode for real-time monitoring of the recurrent laryngealnerve[J]. American Journal of Surgery,2010,199(7):507-514.

  [23] Wu CW,Lu IC,Randolph GW,et al. Investigation of optimalintensity and safety of electrical nerve stimulation during in-traoperative neuromonitoring of the recurrent laryngeal nerve:A prospective porcine model[J]. Head Neck J Sci Spec,2010,32(10):1295-1301.

  [24] Lu IC,Wang HM,Kuo YW,et al. Electromyographic study ofdifferential sensitivity to succinylcholine of the diaphragm,laryngeal and somatic muscles:A swine model[J]. KaohsiungJ Med Sci,2010,26(4):640-646.

  [25] Witzel K,Benhidjeb T. Monitoring of the recurrent laryngealnerve in totally endoscopic thyroid surgery[J]. European Sur-gical Research,2009,43(5):72-76.

  [26] Wu CW,Dionigi G,Sun H,et al. Intraoperative neuromonitoringfor the early detection and prevention of RLN traction injuryin thyroid surgery:a porcine model[J]. Surgery,2014,155(9):329-339.

  [27] Birkholz T,Irouschek A,Labahn D,et al. Electromyographicresponse persists after peripheral transection:endorsement ofcurrent concepts in recurrent laryngeal nerve monitoring in aporcine model[J]. Langenbeck Arch Surg,2010,395(2):121-125.

  [28] Moskalenko V,Huller M,Gasser M,et al. Investigation of theregeneration potential of the recurrent laryngeal nerve (RLN)after compression injury,using neuromonitoring[J]. LangenbeckArch Surg,2009,394(4):469-474.

  [29] Scott AR,Chong PST,Brigger MT,et al. Serial electromyographyof the thyroarytenoid muscles using the NIM-response systemin a canine model of vocal fold paralysis[J]. Ann Oto RhinolLaryn,2009,118(1):56-66.

  [30] Scott AR,Chong PST,Hartnick CJ,et al. Spontaneous and evo-ked laryngeal electromyography of the thyroarytenoid muscles:A canine model for intraoperative recurrent laryngeal nervemonitoring[J]. Ann Oto Rhinol Laryn,2010,119(2):54-63.

  [31] Jiang H,Shen HL,Jiang DZ,et al. Evaluating the safety ofthe harmonic scalpel around the recurrent laryngeal nerve[J].Anz Journal of Surgery,2010,80(3):822-826.

  [32] Scott AR,Chong PS,Hartnick CJ,et al. Spontaneous and evo-ked laryngeal electromyography of the thyroarytenoid muscles:a canine model for intraoperative recurrent laryngeal nervemonitoring[J]. Ann Otol Rhinol Laryngol,2010,119(2):54-63.

  [33] Chu KS ,Wu SH ,Lu IC ,et al. Feasibility of intraoperativeneuromonitoring during thyroid surgery after administration ofnondepolarizing neuromuscular blocking agents [J]. World JSurg,2009,33(7):1408-1413.

  [34] Chu KS,Tsai CJ,Lu IC,et al. Influence of nondepolarizingmuscle relaxants on intraoperative neuromonitoring during thy-roid surgery[J]. J Otolaryngol Head Neck Surg,2010,39(4):397-402.

  [35] Lu IC,Tsai CJ,Wu CW,et al. A comparative study between1 and 2 effective doses of rocuronium for intraoperative neu-romonitoring during thyroid surgery[J]. Surgery,2011,149(4):543-548.

  [36] Lu IC,Chu KS,Tsai CJ,et al. Optimal depth of NIM EMGendotracheal tube for intraoperative neuromonitoring of therecurrent laryngeal nerve during thyroidectomy [J]. World JSurg,2008,32(9):1935-1939.

  [37] Chiang FY,Lu IC,Kuo WR,et al. The mechanism of recur-rent laryngeal nerve injury during thyroid surgery-the appli-cation of intraoperative neuromonitoring[J]. Surgery,2008,143(6):743-749.

  [38] Snyder SK,Lairmore TC,Hendricks JC,et al. Elucidating me-chanisms of recurrent laryngeal nerve injury during thyroide-ctomy and parathyroidectomy [J]. J Am Coll Surgeons,2008,206(1):123-130.

  [39] Dionigi G,Dionigi R. Standardization of intraoperative neuro-monitoring of recurrent laryngeal nerve in thyroid operation:to the editor[J]. World J Surg,2010,34(11):2794-2795.

  [40] Chiang FY,Lu IC,Tsai CJ,et al. Detecting and identifyingnonrecurrent laryngeal nerve with the application of intraope-rative neuromonitoring during thyroid and parathyroid opera-tion[J]. Am J Otolaryngol,2012,33(5):1-5.

  [41] Donatini G,Carnaille B,Dionigi G. Increased detection of non-recurrent inferior laryngeal nerve(NRLN) during thyroid sur-gery using systematic intraoperative neuromonitoring(IONM)[J].World Journal of Surgery,2013,37(1):91-93.

  [42] Brauckhoff M,Machens A,Sekulla C,et al. Latencies shorterthan 3.5 ms after vagus nerve stimulation signify a nonrecu-rrent inferior laryngeal nerve before dissection[J]. Annals ofSurgery,2011,253(6):1172-1177.

  [43] Chiang FY,Lu IC,Chen HC,et al. Intraoperative neuromoni-toring for early localization and identification of recurrent lar-yngeal nerve during thyroid surgery[J]. Kaohsiung J Med Sci,2010,26(12):633-639.

  [44] Chiang FY,Lu IC,Chen HC,et al. Anatomical variations ofrecurrent laryngeal nerve during thyroid surgery:how to iden-tify and handle the variations with intraoperative neuromoni-toring[J]. Kaohsiung J Med Sci,2010,26(11):575-583.

  [45] Serpell JW,Yeung MJ,Grodski S. The motor fibers of therecurrent laryngeal nerve are located in the anterior extral -aryngeal branch[J]. Ann Surg,2010,251(4):773-774.

  [46] Chiang FY,Lu IC,Tsai CJ,et al. Does extensive dissection ofrecurrent laryngeal nerve during thyroid operation increase therisk of nerve injury? Evidence from the application of intrao-perative neuromonitoring[J]. Am J Otolaryng,2011,32(6):499-503.


本文来源http://www.010zaixian.com/shiyongwen/2273661.htm
以上内容来自互联网,请自行判断内容的正确性。若本站收录的信息无意侵犯了贵司版权,请给我们来信(zaixianzuowenhezi@gmail.com),我们会及时处理和回复,谢谢.